{"product_id":"columate-ready-150µm-id-x-250mm-1-6µm-100a-micromics-c18-nanolc-columns-p-n-hc1a-lfst","title":"ColuMate-Ready 150µm ID x 250mm 1.6µm 100Å Micromics C18 NanoLC Columns P\/N HC1A-LFST","description":"\u003clink href=\"https:\/\/fonts.googleapis.com\/css2?family=Poppins:wght@300;400;500;600;700\u0026amp;display=swap\" rel=\"stylesheet\"\u003e\n\n\u003cstyle\u003e\n.micromics-product-content,.micromics-product-content *{box-sizing:border-box;font-family:'Poppins','Montserrat','Helvetica Neue',Arial,sans-serif}\n.micromics-product-content{background:#f5faff;color:#333;line-height:1.65;padding:20px}\n.micromics-product-content .container{max-width:1200px;margin:25px auto 0;background:#fff;border:1px solid #cce0ff;border-radius:14px;overflow:hidden;box-shadow:0 5px 15px rgba(0,0,0,.05)}\n.micromics-product-content .banner-img{display:block;width:100%;height:auto;margin:0}\n.micromics-product-content .product-panel{background:#f5faff;padding:24px;border:1px solid #cce0ff;border-radius:14px}\n.micromics-product-content h2{color:#1a4d8f;font-size:1.9em;font-weight:600;line-height:1.3;letter-spacing:.5px;margin:0 0 12px}\n.micromics-product-content h3{color:#1a4d8f;font-size:1.25em;font-weight:600;line-height:1.3;margin:24px 0 8px}\n.micromics-product-content p{margin:12px 0}\n.micromics-product-content ul{padding-left:20px;margin:0 0 20px}\n.micromics-product-content a{color:#005b96}\n.micromics-product-content .table-scroll{overflow-x:auto}\n.micromics-product-content table{width:100%;border-collapse:collapse;background:#fff}\n.micromics-product-content caption{text-align:left;padding:8px 0;font-weight:700}\n.micromics-product-content th,.micromics-product-content td{padding:12px;text-align:left;vertical-align:top;border-bottom:1px solid #d9e3ec}\n.micromics-product-content .number{text-align:right}\n.micromics-product-content .small-print{font-size:.85em}\n.micromics-product-content .disclosure{color:#465b6d}\n.micromics-product-content .links{margin-top:18px;padding:20px;text-align:center;background:#f8fafd;border-top:1px solid #e6ecf5}\n.micromics-product-content .links a{display:inline-block;padding:12px 20px;margin:8px;background:#003db5;color:#fff;text-decoration:none;border-radius:25px;font-size:.95em;font-weight:500}\n@media(max-width:600px){\n.micromics-product-content{padding:0}\n.micromics-product-content table{min-width:640px}\n.micromics-product-content .links a{display:block;margin:10px auto;max-width:250px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"micromics-product-content\"\u003e\n  \u003cdiv class=\"container\"\u003e\n\n    \u003cimg class=\"banner-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0737\/7856\/1058\/files\/bannercolumates_01.jpg?v=1757561662\" alt=\"ColuMate Banner\"\u003e\n\n    \u003cdiv class=\"product-panel\"\u003e\n\n      \u003ch2\u003e150µm ID x 250mm 1.6µm 100Å ColuMate-Ready NanoLC Columns\u003c\/h2\u003e\n\n      \u003cp\u003e\n        Our \u003cstrong\u003eeffortless plug-and-play capillary column cartridges\u003c\/strong\u003e\n        meet your specific needs, allowing you to tailor the inner diameter\n        (i.d.), length, and emitter options to achieve your desired balance\n        of sensitivity, throughput, and resolution. You can choose between\n        integrated or non-integrated emitters across our column range.\n        This HC1A-LFST configuration features an integrated emitter.\n      \u003c\/p\u003e\n\n      \u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e ⭐low\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e ⭐⭐⭐ High\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThroughput:\u003c\/strong\u003e ⭐⭐⭐ High\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTypical Use Case:\u003c\/strong\u003e Workflows requiring a longer separation bed\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n      \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInner Diameter:\u003c\/strong\u003e 150 µm\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 25 cm\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eStationary Phase:\u003c\/strong\u003e C18, 1.6 µm, 100 Å\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003epH Range:\u003c\/strong\u003e 2–9\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMax Temperature:\u003c\/strong\u003e 70 °C\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 1500 bar (22,000 psi)\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEmitter Option:\u003c\/strong\u003e Integrated\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eInlet Fitting:\u003c\/strong\u003e NanoViper-compatible (1\/16\" female)\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n      \u003csection aria-labelledby=\"hc1a-comparison-title\" style=\"margin-top:24px;\"\u003e\n\n        \u003cp style=\"color:#005b96;font-weight:700;\"\u003e\n          25 cm × 150 µm C18 NanoLC - MicrOmics HC1A-LFST\n        \u003c\/p\u003e\n\n        \u003ch2 id=\"hc1a-comparison-title\" style=\"font-size:1.5em;letter-spacing:0;\"\u003e\n          An alternative to IonOpticks Aurora Ultimate XT columns\n        \u003c\/h2\u003e\n\n        \u003cp\u003e\n          Explore a MicrOmics 150µm ID x 250mm ColuMate-ready column\n          with the same nominal length, inner diameter and C18 chemistry\n          category. Particle specifications, fittings and heating systems\n          differ; confirm your instrument and heater configuration before switching.\n        \u003c\/p\u003e\n\n        \u003cdiv class=\"table-scroll\" role=\"region\" aria-label=\"Column part-number and pricing comparison\" tabindex=\"0\"\u003e\n          \u003ctable\u003e\n            \u003ccaption\u003e25 cm × 150 µm C18 columns - single-column prices in USD\u003c\/caption\u003e\n            \u003cthead\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"col\"\u003eBrand\u003c\/th\u003e\n                \u003cth scope=\"col\"\u003eColumn\u003c\/th\u003e\n                \u003cth scope=\"col\"\u003ePart number\u003c\/th\u003e\n                \u003cth scope=\"col\" class=\"number\"\u003ePrice\u003c\/th\u003e\n                \u003cth scope=\"col\" class=\"number\"\u003eSave with HC1A-LFST\u003c\/th\u003e\n              \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n              \u003ctr style=\"background:#e8f4ef;\"\u003e\n                \u003cth scope=\"row\"\u003eMicrOmics\u003c\/th\u003e\n                \u003ctd\u003e150µm ID x 250mm\u003c\/td\u003e\n                \u003ctd\u003e\u003cstrong\u003eHC1A-LFST\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e\u003cstrong\u003e$950\u003c\/strong\u003e\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e-\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"row\"\u003eIonOpticks\u003c\/th\u003e\n                \u003ctd\u003eAurora Gen4 XT\u003c\/td\u003e\n                \u003ctd\u003eAUR4-250150C18-XT\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e-\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e-\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"row\"\u003eIonOpticks\u003c\/th\u003e\n                \u003ctd\u003eAurora Series 5 XT\u003c\/td\u003e\n                \u003ctd\u003eAUR5-250150C18-XT\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e-\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e-\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n\n        \u003cp class=\"small-print\"\u003e\n          Single-column prices in USD, excluding heaters, starter packs,\n          tax and shipping. A hyphen indicates unavailable pricing or savings.\n          Prices and availability may change.\n        \u003c\/p\u003e\n\n        \u003cp class=\"small-print disclosure\"\u003e\n          The comparison identifies nominal dimensions and C18 chemistry;\n          it does not establish identical performance or hardware compatibility.\n          IonOpticks and Aurora are trademarks of Ion Opticks Pty Ltd.\n          MicrOmics Technologies is not affiliated with, sponsored by,\n          or endorsed by IonOpticks.\n        \u003c\/p\u003e\n\n        \u003ch3\u003eASMS 2026: performance evidence from the ColuMate platform\u003c\/h3\u003e\n\n        \u003cp\u003e\n          Our ASMS poster reports comparable proteomics performance in a study\n          of \u003cstrong\u003e75 µm × 15 cm\u003c\/strong\u003e column configurations.\n          The results below compare MicrOmics with the competitor system\n          evaluated in the poster.\n        \u003c\/p\u003e\n\n        \u003cdiv class=\"table-scroll\" role=\"region\" aria-label=\"ASMS study results\" tabindex=\"0\"\u003e\n          \u003ctable\u003e\n            \u003ccaption\u003eResults reported in the ASMS poster\u003c\/caption\u003e\n            \u003cthead\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"col\"\u003eMeasurement\u003c\/th\u003e\n                \u003cth scope=\"col\" class=\"number\"\u003eMicrOmics\u003c\/th\u003e\n                \u003cth scope=\"col\" class=\"number\"\u003eCompetitor\u003c\/th\u003e\n              \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"row\"\u003eProtein IDs - 10 ng HeLa\u003c\/th\u003e\n                \u003ctd class=\"number\"\u003e5,408\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e5,067\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"row\"\u003eProtein IDs - 250 pg HeLa\u003c\/th\u003e\n                \u003ctd class=\"number\"\u003e2,264\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e2,179\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003cth scope=\"row\"\u003ePeak width, FWHM - 10 ng HeLa\u003c\/th\u003e\n                \u003ctd class=\"number\"\u003e3.80 s\u003c\/td\u003e\n                \u003ctd class=\"number\"\u003e4.22 s\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n\n        \u003cp class=\"small-print\"\u003e\n          Study conditions: triplicate QC HeLa digest; 50 °C;\n          20-minute active gradient for MicrOmics and Competitor;\n          Thermo U3000 NanoLC, Exploris 480 with FAIMS Pro; DIA-NN analysis.\n        \u003c\/p\u003e\n\n        \u003cp class=\"small-print disclosure\"\u003e\n          \u003cstrong\u003eData disclosure:\u003c\/strong\u003e\n          These data were generated by MicrOmics Technologies and presented\n          in our ASMS 2026 poster. The authors are MicrOmics employees with\n          a financial interest in the company. Testing used\n          75 µm × 15 cm column configurations; these results\n          do not establish performance equivalence for this\n          150 µm × 25 cm configuration. Results depend on the\n          sample, instrument, method and operating conditions.\n          See the full poster for methods and context.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n          \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0737\/7856\/1058\/files\/ASMS_2026_MicrOmics_Heater_comparison.pdf?v=1784069031\"\u003e\n            \u003cstrong\u003eRead the ASMS 2026 poster\u003c\/strong\u003e\n          \u003c\/a\u003e\n        \u003c\/p\u003e\n\n        \u003ch3\u003eClear pricing for confident planning\u003c\/h3\u003e\n\n        \u003cp\u003e\n          Know what your column costs before you contact sales.\n          Our\n          \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0737\/7856\/1058\/files\/MicrOmics_2026_Column_Product_List.pdf?v=1790278694\"\u003e\n            full 2026 column price book (PDF)\n          \u003c\/a\u003e\n          brings together part numbers, specifications, single-column and\n          value-pack prices, configuration adjustments, and typical lead times.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n          We publish the same baseline pricing and pack discounts for everyone:\n          5% off packs of five and 10% off packs of ten columns with the same\n          part number. Published configuration costs help you understand how\n          dimensions and connection options affect your budget.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n          Read\n          \u003ca href=\"https:\/\/micromicstech.com\/blogs\/news\/transparent-nanolc-column-pricing-2026\"\u003e\n            What Does a NanoLC Column Cost? Our Approach to Transparent Pricing\n          \u003c\/a\u003e\n          to learn how upfront pricing helps reduce quote requests\n          and simplify purchasing.\n        \u003c\/p\u003e\n\n        \u003ch3\u003eFind the right column for your workflow\u003c\/h3\u003e\n\n        \u003cp\u003e\n          This column uses 1.6 µm, 100 Å C18 particles and an\n          integrated emitter in the ColuMate cartridge format.\n          Confirm your instrument and heater configuration before ordering.\n        \u003c\/p\u003e\n\n        \u003cp\u003e\n          \u003ca href=\"https:\/\/micromicstech.com\/pages\/column-trial\"\u003e\n            \u003cstrong\u003eExplore the column trial\u003c\/strong\u003e\n          \u003c\/a\u003e\n        \u003c\/p\u003e\n\n      \u003c\/section\u003e\n\n      \u003cdiv class=\"links\"\u003e\n        \u003cp style=\"color:#1a4d8f;\"\u003eFor more information, visit\u003c\/p\u003e\n        \u003ca href=\"https:\/\/micromicstech.com\/pages\/columate-capillary-heater\"\u003e\n          ColuMate Technologies Page\n        \u003c\/a\u003e\n        \u003ca href=\"https:\/\/micromicstech.com\/pages\/column-technologies\"\u003e\n          Column Technologies Page\n        \u003c\/a\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"MicrOmics Technologies","offers":[{"title":"1 pk","offer_id":69979955036194,"sku":"HC1A-LFST","price":950.0,"currency_code":"USD","in_stock":true},{"title":"5 pk","offer_id":69979955068962,"sku":"HC1A-LFST-5pk","price":4512.0,"currency_code":"USD","in_stock":true},{"title":"10 pk","offer_id":69979955101730,"sku":"HC1A-LFST-10pk","price":8550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0737\/7856\/1058\/files\/15cm_2.jpg?v=1764712741","url":"https:\/\/micromicstech.com\/products\/columate-ready-150%c2%b5m-id-x-250mm-1-6%c2%b5m-100a-micromics-c18-nanolc-columns-p-n-hc1a-lfst","provider":"MicrOmics Technologies","version":"1.0","type":"link"}